Chapter 2 - Hardware Installation
2-28
Mounting the MGC+50 on a Rack
The MGC+50 can be mounted in a 19” rack using two mounting plates (Kit
2012A). The side plates are usually mounted when shipped, but if not, follow
the directions below to install the mounted plates on the MGC+50 and then
mount the MGC+50 on the 19” rack.
To install and mount the MGC+50:
1. Make sure that the MGC+50 power is turned OFF and it is disconnected
from the AC power.
2. Remove the five nylon plug hole covers from the MGC+50 protective
side covers (using a slotted screwdriver).
3. Using an Allen wrench (M4), remove the five screws from the MGC+50
side covers.
4. Remove the MGC+50 side covers from both sides.
5. To remove the plate from both MGC+50 sides, the side screws have to be
removed. To remove the screws from the left side of the MGC+, the
Control Board, Server panel, Functional modules and power supply must
be removed first. These procedures are described in Chapter 5 of this
manual. For detailed procedures, see Chapter 5, “Replacing the Main
Control Module” on page 5-17. For instructions on how to remove the
power supply, see Chapter 5, “Replacing the Power Supply Module on
the MGC+50” on page 5-11.
front
remove
side cover